Article: In vivo dynamic clamp study of I(h) in the mouse inferior colliculus.
Full Text (publisher's website) ; Article Metadata ; Article Data (extracted) Nagtegaal AP; Borst JG J. Neurophysiol., 2010
Inferred neuron-electrophysiology data values
Neuron Type | Neuron Description | Ephys Prop | Extracted Value | Standardized Value | Content Source |
---|---|---|---|---|---|
Inferior colliculus neuron | inferior colliculus hyperpolarization-activated mixed cation current neuron | input resistance (MΩ) | 78.0 ± 5.6 | 78.0 (MΩ) | Data Table |
Inferior colliculus neuron | inferior colliculus hyperpolarization-activated mixed cation current neuron | resting membrane potential (mV) | -62.7 ± 1.2 | -62.7 (mV) | Data Table |
Inferior colliculus neuron | inferior colliculus hyperpolarization-activated mixed cation current neuron | sag amplitude (mV) | -4.2 ± 0.09 (19) | -4.2 (mV) | Data Table |
Inferior colliculus neuron | inferior colliculus hyperpolarization-activated mixed cation current neuron | sag ratio | 24.0 ± 1.0 | 0.24 (ratio) | Data Table |
Inferior colliculus neuron | inferior colliculus hyperpolarization-activated mixed cation current neuron | spike threshold (mV) | -50.1 ± 1.5 | -50.1 (mV) | Data Table |
Metadata values
Experimental condition | Value |
---|---|
Species | Mice |
ElectrodeType | Patch-clamp |
Strain | C57BL |
InternalSolution | 5.0 |
ExternalSolution | 5.0 |
PrepType | in vivo |
JxnPotential | Corrected |
AnimalAge | 21.0 - 35.0 |
RecTemp | 37.0 |
internal_0_pH | 7.2 |
internal_0_Mg | 4.0 |
internal_0_Na | 20.6 |
internal_0_K | 146.0 |
internal_0_GTP | 0.3 |
internal_0_ATP | 4.0 |
internal_0_EGTA | 0.5 |
internal_0_HEPES | 10.0 |
internal_0_Cl | 20.0 |
external_0_pH | 7.2 |
external_0_Mg | 1.0 |
external_0_Na | 135.0 |
external_0_K | 5.4 |
external_0_HEPES | 5.0 |
external_0_Cl | 146.0 |
external_0_Ca | 1.8 |
Data table listing
Data Table | Article Title | Authors | Journal | Year | Table needs expert? | Ephys table mentions | Curated by | Times validated |
---|---|---|---|---|---|---|---|---|
149 | In vivo dynamic clamp study of I(h) in the mouse inferior colliculus. | Nagtegaal AP; Borst JG | J. Neurophysiol. | 2010 | False | 5 | Shreejoy Tripathy, James liu, Dmitry Tebaykin, | 1 |