AboutNeuron TypesElectrophysiology PropertiesArticlesFAQsData/APIGet Involved

Article: Intrinsic electrophysiological properties of entorhinal cortex stellate cells and their contribution to grid cell firing fields.

Full Text (publisher's website) ; Article Metadata ; Article Data (extracted)
Pastoll H; Ramsden HL; Nolan MF
Front Neural Circuits, 2012


Resonant properties.

Perforated patch (n = 5) Whole-cell (n = 14) p Test
Q (resting) 2.0 ± 0.2 1.7 ± 0.1 0.1 ANCOVA
Q (peri-threshold) 1.6 ± 0.1 1.8 ± 0.1 0.3 ANCOVA
FZ-max (Hz) (resting) 5.9 ± 1.0 6.1 ± 0.5 0.84 ANCOVA
FZ-max (Hz) (peri-threshold) 4.7 ± 0.9 4.4 ± 0.4 0.56 ANCOVA
Resting Peri-threshold p Test
Q (perforated patch) 2.0 ± 0.2 1.6 ± 0.1 0.03 Paired t-test
Q (whole-cell) 1.7 ± 0.1 1.8 ± 0.1 0.4 Paired t-test
FZ-max (Hz) (perforated patch) 5.9 ± 1.0 4.7 ± 0.9 0.02 Paired t-test
FZ-max (Hz) (whole-cell) 6.1 ± 0.5 4.4 ± 0.4 2.8e-6 Paired t-test

Report miscurated data

Inferred neuron-electrophysiology data values

Neuron Type Neuron Description Ephys Prop Extracted Value Standardized Value Content Source