AboutNeuron TypesElectrophysiology PropertiesArticlesFAQsData/APIGet Involved

Olfactory cortex horizontal cell (Definition)

Electrophysiological properties of Olfactory cortex horizontal cells from literature:

Neuron electrophysiology data values (Table form)

Neuron Type Neuron Description Ephys Prop Article Extracted Value Standardized Value Content Source
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal weakly adapting low frequency cell input resistance The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 97.2 ± 3.4 (66) 97.2 (MΩ) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical slow adapting low frequency interneuron input resistance The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 134.4 ± 15.9 (10) 134.4 (MΩ) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting low frequency interneuron input resistance The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 174.2 ± 5.8 (71) 174.2 (MΩ) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting high frequency interneuron input resistance The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 302.3 ± 12.5 (42) 302.3 (MΩ) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical slow adapting low frequency interneuron resting membrane potential The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) -70.6 ± 2.9 (10) -70.6 (mV) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting low frequency interneuron resting membrane potential The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) -76.0 ± 0.9 (71) -76.0 (mV) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting high frequency interneuron resting membrane potential The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) -76.2 ± 1.3 (42) -76.2 (mV) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal weakly adapting low frequency cell resting membrane potential The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 72.7 ± 0.8 (66) -72.7 (mV) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting low frequency interneuron rheobase The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 138.0 ± 7.6 (71) 138.0 (pA) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical adapting high frequency interneuron rheobase The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 119.0 ± 6.3 (42) 119.0 (pA) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal weakly adapting low frequency cell rheobase The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 182.6 ± 10.0 (66) 182.6 (pA) Data Table
Olfactory cortex horizontal cell Anterior Piriform cortex multipolar/horizontal/vertical slow adapting low frequency interneuron rheobase The loss of interneuron functional diversity in the piriform cortex after induction of experimental epilepsy. (NeuroElectro data) (PubMed) 190.0 ± 7.6 (10) 190.0 (pA) Data Table
View data in graphical form Report miscurated data