AboutNeuron TypesElectrophysiology PropertiesArticlesFAQsData/APIGet Involved

Article: The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm.

Full Text (publisher's website) ; Article Metadata ; Article Data (extracted)
Tazerart S; Vinay L; Brocard F
J. Neurosci., 2008

Inferred neuron-electrophysiology data values

Neuron Type Neuron Description Ephys Prop Extracted Value Standardized Value Content Source
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron input resistance (MΩ) 1050.0 ± 187.0 (8) 1050.0 (MΩ) Data Table
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron resting membrane potential (mV) -63.9 ± 2.3 (8) -63.9 (mV) Data Table
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron rheobase (pA) 18.5 ± 3.7 (8) 18.5 (pA) Data Table
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron spike amplitude (mV) 50.5 ± 3.1 (8) 50.5 (mV) Data Table
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron spike half-width (ms) 1.91 ± 0.07 (8) 1.91 (ms) Data Table
Other Upper lumbar spinal cord ventromedial gray matter locomotor interneuron spike threshold (mV) -50.7 ± 1.6 (8) -50.7 (mV) Data Table

Report miscurated data

Metadata values

Experimental condition Value
Species Rats
Species Mice
ElectrodeType Patch-clamp
PrepType in vitro
Strain Wistar
ExternalSolution 5.0
external_1_pH 7.4
external_1_Mg 1.3
external_1_Ca 1.2
external_1_Na 146.25
external_1_Cl 125.4
external_1_K 3.0
InternalSolution 5.0
internal_1_pH 7.3
internal_1_Mg 2.0
internal_1_Na 5.0
internal_1_Cl 149.0
internal_1_K 30.0
JxnPotential Corrected
AnimalAge 1.0 - 5.0
RecTemp 24.0 - 26.0
JxnOffset 14.0
internal_0_pH 7.3
internal_0_Mg 2.0
internal_0_Na 5.0
internal_0_K 140.0
internal_0_GTP 0.4
internal_0_ATP 2.0
internal_0_EGTA 0.5
internal_0_HEPES 10.0
internal_0_Cl 9.0
external_0_pH 7.4
external_0_Mg 1.3
external_0_Na 155.58
external_0_K 4.0
external_0_Cl 141.5
external_0_Ca 3.75
external_0_glucose 10.0

Data table listing

Data Table Article Title Authors Journal Year Table needs expert? Ephys table mentions Curated by Times validated
2030 The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm. Tazerart S; Vinay L; Brocard F J. Neurosci. 2008 False 6 Shreejoy Tripathy, Ryan Sefidpour, Athanasios Kritharis, Kerrie Tsigounis, Nathalie Binnion, 4
2028 The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm. Tazerart S; Vinay L; Brocard F J. Neurosci. 2008 False 4 0
2029 The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm. Tazerart S; Vinay L; Brocard F J. Neurosci. 2008 False 4 0
2031 The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm. Tazerart S; Vinay L; Brocard F J. Neurosci. 2008 False 0 None
2032 The persistent sodium current generates pacemaker activities in the central pattern generator for locomotion and regulates the locomotor rhythm. Tazerart S; Vinay L; Brocard F J. Neurosci. 2008 False 0 None