AboutNeuron TypesElectrophysiology PropertiesArticlesFAQsData/APIGet Involved

Article: Chronic hypobaric hypoxia induces tolerance to acute hypoxia and up-regulation in alpha-2 adrenoceptor in rat locus coeruleus.

Full Text (publisher's website) ; Article Metadata ; Article Data (extracted)
Chang KC; Yang JJ; Liao JF; Wang CH; Chiu TH; Hsu FC
Brain Res., 2006


Table 1 Resting membrane properties of the control and exposed LC neurons
Control (n = 84)Exposed (n = 105)
Resting membrane potential (MP) (mV)−55.8 ± 0.6−56.3 ± 0.8
Membrane input resistance (IR) (MΩ)134 ± 8143 ± 9
Spontaneous firing rate (FR) (Hz)2.8 ± 0.21.8 ± 0.1⁎⁎⁎
Data were presented as mean ± SEM.⁎⁎⁎P < 0.001 compared to control.

Report miscurated data

Inferred neuron-electrophysiology data values

Neuron Type Neuron Description Ephys Prop Extracted Value Standardized Value Content Source
Locus coeruleus noradrenergic neuron Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron spontaneous firing rate 2.8 ± 0.2 2.8 (Hz) Data Table
Locus coeruleus noradrenergic neuron Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron resting membrane potential -55.8 ± 0.6 -55.8 (mV) Data Table
Locus coeruleus noradrenergic neuron Locus coeruleus alpha-2 adrenoceptor expressing noradrenergic neuron input resistance 134.0 ± 8.0 134.0 (MΩ) Data Table